UNI-T

UNI-T UT17B MAX True RMS Digital Multimeter CAT III 600V

True RMS with 6000 counts, Voltage up to 1000 V, Current up to 10 A, Temperature -55 to 500 °C, CAT III 600V protection class

The UNI-T UT17B MAX is a True RMS digital multimeter with a 6000-count display for voltage, current, resistance, capacitance, frequency, and temperature. It covers DC and AC voltage up to 1000 V as well as DC and AC current up to 10 A and measures temperatures from -55 °C to 500 °C. CAT III 600V and numerous convenience features make it suitable for professional daily use.

CHF93.95
Incl. VAT and recycling fee
Delivery time: Delivered by Th. 5.11 Delivered by Th. 5.11 More than 10 available
  • Free shipping with Swiss Post
  • Us de Bärge – shipped from Thusis
  • 60 days free returns
  • Price match guarantee
TWINT Visa Mastercard PostFinance Pay PayPal American Express

Description

The UNI-T UT17B MAX is a True RMS digital multimeter that, in addition to classic electrical quantities, also measures temperature. It covers DC and AC voltage up to 1000 V, DC and AC current up to 10 A, resistance up to 60 MΩ, capacitance up to 6000 µF, and frequency up to 10 MHz. The temperature range of -55 °C to 500 °C expands the field of application to service and diagnostic work, where thermal measurements are also required. A Type K thermocouple is included, so this function is immediately usable without additional procurement.

The 6000-count display is supplemented by continuity and diode testing, data hold function, MAX/MIN and relative modes. Adjustable backlight, automatic and manual range selection, automatic shutdown with wake-up by pressing any key, as well as visual and acoustic alarms provide comfortable daily measurement operations. An alarm for incorrect connection and the overvoltage category CAT III 600V increase operational safety. Thus the UT17B MAX is aimed at professionals who want to reliably capture temperature beyond basic measurements.

Specifications

General
Type True RMS Digital Multimeter
Color Red and grey
Technical data
DC voltage range 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1000 V ±(0.4%+3)
AC voltage range 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1000 V ±(0.5%+5)
VFD range 600.0 V ±(8%)
AC current range 600.0 µA / 6000 µA / 60.00 mA / 600.0 mA / 6.000 A / 10.00 A ±(1.2%+3)
DC current range 600.0 µA / 6000 µA / 60.00 mA / 600.0 mA / 6.000 A / 10.00 A ±(1.2%+3)
Resistance range 600.0 Ω to 60.00 MΩ ±(0.5%+2)
Capacitance range 6.000 nF to 6000 µF ±(2.0%+5)
Frequency range 10 Hz to 10 MHz ±(0.1%+3)
Duty cycle range 1% to 99.9% ±(1.0%+4)
Temperature range -55 to 500 ±2 °C °C
Display 6000
Continuity test Yes
Diode test Yes
Data hold function Yes
MAX/MIN mode Yes
Relative mode Yes
Backlight Adjustable
Range selection Automatic and manual
Automatic shutdown Yes
Wake-up by any key Yes
Visual and acoustic alarm Yes
Alarm for incorrect connection Yes
Overvoltage category CAT III 600V
Power supply 2x 1.5 V AA Batteries
Compatibility
Included thermocouple Type K

More Information

More Information
Backlight Adjustable
Contact us on WhatsApp